ANESTHESIA MACHINE PRO 45 S




 Primary features
incorporates extra-reliable, patented "Low oxygen conc. avoidance system".
High precision triple-column flowmeter allows easy, quick value reading.
Acoma original one-touch vaporizer attachment / detachment design. Anesthetic gas mixture prevention device. Simultaneous one-touch control of the anesthetic circuit and ventilator possible by manipulating the selector cock (optional feature).
Rationaly designed respiratoly circuit section realizes a top level of usage ease.
Multiple monitoring system incorporated enhances safety checks for abnormalities.
Desk-like table top alows for ready record keeping.


Low flow rate compatible type also available. With this type, the graduations in the low flow rate range of '0-1L/min' are magnified for easier display reading. Also incorporated are precise flow rate control function as well as a safety device to assure O2 gas flow (0.25L/min) every time before N2O gas is sent.

 Principal components

Patented interlocking gear flowmeter / Auto on oxygen monitor / "Safety Block" / Auto/manual remote terminal / Analog circuit pressure gauge / Two-storage drawers

PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

ANESTHESIA MACHINE VIGOR 21 DX


Primary features
Simplicity-centered anesthesia unit, provided with a compact/high-mobility respiratory circuit section as well as designed prioritizing practical-use handling, incorporates all the essential functions needed for anesthetic procedures through trouble-free controls.
With the built-in safety device, it is completely ensured that the N
2O gas flow will not turn on unless the O2 gas flow goes over '1.8L/min'.
For added convenience, even if inadvertently forgetting to turn the built-in O
2 monitor on, this switched monitor automatically turns on if O2 
flow goes over '1.8L/min'.

 Principal components

Special flow meter to automatically ensure minimum O2 flow / Versatile auto-switching O2monitor with manual ON/OFF and one-touch calibration / Highly precise, fully 360 degree horizontally rotatable circuit pressure gauge / One-touch auto/manual selector cock / APL value / Auxiliary cylinder yoke (for O2) / independent gas supply pressure gauges for O2 and N2O / monitor shelf can hold units totaling up to 20kgs. / Auxiliary power outlets / table top usable for record keeping / Large-caster base for top mobility

PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

ANESTHESIA MACHINE FO 20 S




Reliable security
·         N2O and O2 metering is jointly controlled by a special mechanically interlocking gear system, that ensures patient safety by controlling the minimum oxygen concentration so that it never goes below 30% (±3 Vol. %, when O2 flow is over 1 L/min.). (PAT. 1737472)
·         If O2 supply pressure drops below 240 to 260 kPa, whistle sounds.
·         If O2 supply pressure falls below 100kPa (approx. 1kgf/cm2), the N2O flow into the circuit is automatically suspended for assurance of patient safety.

 Easy operation
·         Convenient, easy disposal of surplus gas
·         Easy-to-handle canister
·         One-touch oxygen flushing

 Compact and Customizable.
·         FO-20S can be carried conveniently anywhere by means of the carrying handle.
·         An Anesthetic ventilator (such as Acoma PRO-V mkII,ARF-900II & ACE-3000) can be installed within the mobile stand.
·         A built-in drawer on small mobile stand provides readily available storage space for various instruments, accessories, and other small items.(option)
·         Large castors for smooth, easy unit mobility combined with firm locking.

·         Rail type mount for 2 Vaporizers is optionally available for stand C.

PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

LUNG VENTILATOR ART 21 EX


 Primary features


The combination of the "flow trigger" method and rapid response valves greatly reduces trigger delay . nt size="-1">(comparison with our other products) 

SIMV pressure support ventilation, and apnea backup ventilation function for CPAP mode

If AC power is cut, the driving gas switches to O2 to maintain ventilation. (when using the blower ART-21B)




PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

LUNG VENTILATOR MOBILE 1000 II



 Primary features
Versatile 3-way power sourcing -- 1. 'AC source' (w/Dedicated power unit connected), 2. 'External source' (powered through such as a car battery), and 3. 'Internal source'.

Should either AC power fail or DC voltage drop to 11V or less, continuous ventilation is ensured by the Mobile-1000 power drive's instantaneous/automatic switching to the back up 'internal battery'.
Under average conditions, ventilation will continue for approx. 1 hour, provided that the internal battery is recharged to 90%.

Should all the batteries become depleted and there's no alternative power source, operation can be swiched to manual ventilation by manipulating the furnished 'breathing bag'.

Slim, compact and relatively light unit can be conveniently carried anywhere such as for first aid and patient transport.

 Principal components

Internal battery (DC) / Power unit (AC) / PEEP compensation assistor ventilation function / SIGH function / Spirometer incorporated / Circuit pressure gauge doubles as a power voltage checker / Internal battery recharging monitor / Hour meter / Heater-humidifier / AIR-oxygen mixing function / Safety & alarm devices.



PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

LUNG VENTILATOR ICV 60



 Primary features
Based on a time-cycling flow generator, this unit offers an I/E ratio automatically calculated by presetting respiratory rate and inspiratory time, and then only setting tidal volume.
Further, highly rationalized engineering has resulted in an especially effective inspiratory/expiratory flow separation system which realizes suppressed respiratory resistance, outstandingly improved economics, as well as enhanced monitoring and alarm systems.

 Principal components

Circuit pressure gauge for measuring/digitally displaying maximum, mean and minimum pressure values / High performance O2/AIR blender / Expiratory phase constant flow leads to inspiratory resistance reduction during spontaneous breathing / Manual inspiration button to permit SIGH realization while inspiratory action contineues / If expiratory phase pressure rises, PEEP function activates to lower it / Water trap

PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

ELECTROSURGICAL UNIT ACUTOR SR II




 Primary features
Specially engineered hemostatic level control system ensures continual stable, accurate output even against excessive impedance variation.
Superior performance fully exhibited in such special procedures as transurethral resection (TUR).

Highly efficient output circuit delivers strong, continuous output performance, yet at a lower calorific value.

Convenient, dual-mode selection function incorporated:
Twin button allow for expeditious switching between 'monopolar' and 'bipolar' modes.
In the 'bipolar' mode, output with an acute responsibility is realized instantly at the preset level.

Integrated spray coagulation function allows for wider applications such as for speedy hemostatic precedures.

Bipolar output at a markedly reduced voltage has resulted in minimized electrical discharge that further decreases the chance of burning occurring at the tip of the forceps.

Easily adjustable hemostatic functioning offers greater matching of specific requirements -- 4-steps ('0-3') hemostatic level selectability permits more refined cutting capability.
E.g. Level '0' is pure (100%) cutting, without any accompanied hemostasis.

Incorporated foot control output port on the front of the unit allows for integrated operation of peripheral instruments such as an endoscope.

Carefully engineered foolproof mechnisms utilized on all connections realizes an extra-high degree of safety --All the accessory connection ports are specifically configured to prevent erroneous connection such as having each shaped differently to avoid interchangeability.

incorporated safety/alarm devices help prevent patient electrode cord abnormality as well as overload (shortcircuiting within the output section). For added safety, this unit is equipped with an additional protective cord (grounding wire; a relevant alarm also furnished) to prevent electric shock or heat injury which may be caused by incomplete grounding.

Compact, rationally designed electrosurgical unit offers a rich variety of functions through simple handling.


PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

SUCTION UNIT





 Primary features
Designed for extra-large capacity requirements, the unit is equipped with two 3,000ml suction bottles. Ensurings further safety, when the first bottle is full, the flow automatically switches to the second one, and if both become full, suction stops automatically.

The convenient stainless steel tray on the top can be used for many purposes.

Handly rear service pocket offers extra storage space for foot switch, etc.

When the main power switch is turned off, the foot switch can be used for extra easy intermittent suctioning.


PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

ULTRASOUND NEBULIZER




The physician's choice for effective inhalation therapy through delivery of a continually stable, homogeneous ultra-fine mist.


























Water supply bottle is optionally available.

 Primary features

Offering superior versatility, safety, plus handling and maintenance ease, this nebulizer produces a stable, ultra-fine 1-5 micron aerosol.

It also features 1-60 min, timed or continuous operation, and a low water level / internal abnormally high temperature warning device.


PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999

VAPORIZER MK II







Long-life, reliability and stable concentration control in a full line of high-precision vaporizers


VAPORIZER MK II



 Primary features

Large calorific capacity and an automatic compensation mechanism ensure constant performance for concentration control.

Click-stop dial manipulated from above. Reliable/delicate concentration adjustments possible merely with the dial turning.

Auto lock device incorporated to assure automatic locking when the dial is set to OFF.


PT. MEGA MEDIKA JAYA
Email : marketing_megamed@yahoo.com
PH : 021-78830461
HP : 081213786999
HP : 087878196999

HP : 085770226999